smartd_log plugin: configuration file added
Ilya committed
Feb 1, 2017 at 15:27 UTC
1a5e7cfa28e7930185b5bba722a9df6bea710119
1 file changed
+85
conf.d/python.d/smartd_log.conf
new
+85
@@ -0,0 +1,85 @@
1
+# netdata python.d.plugin configuration for smartd log
2
+#
3
+# This file is in YaML format. Generally the format is:
4
+#
5
+# name: value
6
+#
7
+# There are 2 sections:
8
+# - global variables
9
+# - one or more JOBS
10
+#
11
+# JOBS allow you to collect values from multiple sources.
12
+# Each source will have its own set of charts.
13
+#
14
+# JOB parameters have to be indented (using spaces only, example below).
15
+
16
+# ----------------------------------------------------------------------
17
+# Global Variables
18
+# These variables set the defaults for all JOBs, however each JOB
19
+# may define its own, overriding the defaults.
20
+
21
+# update_every sets the default data collection frequency.
22
+# If unset, the python.d.plugin default is used.
23
+# update_every: 1
24
+
25
+# priority controls the order of charts at the netdata dashboard.
26
+# Lower numbers move the charts towards the top of the page.
27
+# If unset, the default for python.d.plugin is used.
28
+# priority: 60000
29
+
30
+# retries sets the number of retries to be made in case of failures.
31
+# If unset, the default for python.d.plugin is used.
32
+# Attempts to restore the service are made once every update_every
33
+# and only if the module has collected values in the past.
34
+# retries: 5
35
+
36
+# ----------------------------------------------------------------------
37
+# JOBS (data collection sources)
38
+#
39
+# The default JOBS share the same *name*. JOBS with the same name
40
+# are mutually exclusive. Only one of them will be allowed running at
41
+# any time. This allows autodetection to try several alternatives and
42
+# pick the one that works.
43
+#
44
+# Any number of jobs is supported.
45
+#
46
+# All python.d.plugin JOBS (for all its modules) support a set of
47
+# predefined parameters. These are:
48
+#
49
+# job_name:
50
+# name: myname # the JOB's name as it will appear at the
51
+# # dashboard (by default is the job_name)
52
+# # JOBs sharing a name are mutually exclusive
53
+# update_every: 1 # the JOB's data collection frequency
54
+# priority: 60000 # the JOB's order on the dashboard
55
+# retries: 5 # the JOB's number of restoration attempts
56
+#
57
+# Additionally to the above, smartd_log also supports the following:
58
+#
59
+# log_path: '/path/to/smartdlogs' # path to smartd log files. Default is /var/log/smartd
60
+# raw_values: no # raw or normalized values on charts. Default is normalized.
61
+# smart_attributes: '1 2 3 4 44' # add additional smart attributes charts. Default are ['1', '4', '5', '7', '9', '12', '193', '194', '197', '198', '200'].
62
+#
63
+# ----------------------------------------------------------------------
64
+# Additional information
65
+# Plugin reads smartd log files (-A option).
66
+# You need to add (man smartd) to /etc/default/smartmontools '-i 600 -A /var/log/smartd/' to pass additional options to smartd on startup
67
+# Then restart smartd service and check /path/log/smartdlogs
68
+# ls /var/log/smartd/
69
+# CDC_WD10EZEX_00BN5A0-WD_WCC3F7FLVZS9.ata.csv WDC_WD10EZEX_00BN5A0-WD_WCC3F7FLVZS9.ata.csv ZDC_WD10EZEX_00BN5A0-WD_WCC3F7FLVZS9.ata.csv
70
+#
71
+# Smartd APPEND logs at every run. Its NOT RECOMMENDED to set '-i' option below 60 sec.
72
+# STRONGLY RECOMMENDED to create smartd conf file for logrotate
73
+#
74
+# RAW vs NORMALIZED values
75
+# "Normalized value", commonly referred to as just "value". This is a most universal measurement, on the scale from 0 (bad) to some maximum (good) value.
76
+# Maximum values are typically 100, 200 or 253. Rule of thumb is: high values are good, low values are bad.
77
+#
78
+# "Raw value" - the value of the attribute as it is tracked by the device, before any normalization takes place.
79
+# Some raw numbers provide valuable insight when properly interpreted. These cases will be discussed later on.
80
+# Raw values are typically listed in hexadecimal numbers. The raw value has different structure for different vendors and is often not meaningful as a decimal number.
81
+#
82
+#
83
+# JOB configuration
84
+#
85
+log_path: '/var/log/smartd'