docs: restructure Setup, update SNMP prerequisites, and fix SNMP options (#20977)

Ilya Mashchenko committed Sep 14, 2025 at 19:02 UTC 8b7837ae9dc1ee3bf04fc581c959232481cbe670
3 files changed +36 -15
integrations/templates/setup.md
+22 -3
@@ -10,6 +10,23 @@
10 There is no configuration needed for this integration.
11 [% else %]
12
13 +[% if entry.meta.plugin_name == 'go.d.plugin' %]
14 +
15 +You can configure the **[[ entry.meta.module_name ]]** collector in two ways:
16 +
17 +| Method | Best for | How to |
18 +|-----------------------|------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------|
19 +| [**UI**](#via-ui) | Fast setup without editing files | Go to **Nodes → Configure this node → Collectors → Jobs**, search for **[[ entry.meta.module_name ]]**, then click **+** to add a job. |
20 +| [**File**](#via-file) | If you prefer configuring via file, or need to automate deployments (e.g., with Ansible) | Edit `[[ entry.setup.configuration.file.name ]]` and add a job. |
21 +
22 +:::important
23 +
24 +UI configuration requires paid Netdata Cloud plan. File-based configuration uses the same options and is useful if you prefer configuring via file or need to automate deployments.
25 +
26 +:::
27 +
28 +[% endif %]
29 +
30 [% if entry.setup.description %]
31 [[ entry.setup.description ]]
32 [% else %]
@@ -63,14 +80,16 @@ There are no configuration options.
80 [% if entry.meta.plugin_name == 'go.d.plugin' %]
81 #### via UI
82
66 -The **[[ entry.meta.module_name ]]** collector can be configured directly through the Netdata web interface:
83 +Configure the **[[ entry.meta.module_name ]]** collector from the Netdata web interface:
84
85 1. Go to **Nodes**.
69 -2. Select the node **where you want the [[ entry.meta.module_name ]] data-collection job to run** and click the :gear: (**Configure this node**). This node will be responsible for collecting metrics.
86 +2. Select the node **where you want the [[ entry.meta.module_name ]] data-collection job to run** and click the :gear: (**Configure this node**). That node will run the data collection.
87 3. The **Collectors → Jobs** view opens by default.
88 4. In the Search box, type _[[ entry.meta.module_name ]]_ (or scroll the list) to locate the **[[ entry.meta.module_name ]]** collector.
89 5. Click the **+** next to the **[[ entry.meta.module_name ]]** collector to add a new job.
73 -6. Fill in the job fields, then **Test** the configuration and **Submit**.
90 +6. Fill in the job fields, then click **Test** to verify the configuration and **Submit** to save.
91 + - **Test** runs the job with the provided settings and shows whether data can be collected.
92 + - If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.
93
94 [% endif %]
95
integrations/templates/setup/sample-go-config.md
+1 -1
@@ -5,5 +5,5 @@ update_every: 1
5 autodetection_retry: 0
6 jobs:
7 - name: some_name1
8 - - name: some_name1
8 + - name: some_name2
9 ```
src/go/plugin/go.d/collector/snmp/metadata.yaml
+13 -11
@@ -65,7 +65,13 @@ modules:
65 **Concurrent access**: If multiple collectors or tools access the same SNMP device simultaneously, data points might be skipped. This is a limitation of the device itself, not this collector. To mitigate this, consider increasing the collection interval (update_every) to reduce the frequency of requests.
66 setup:
67 prerequisites:
68 - list: []
68 + list:
69 + - title: "Prepare the SNMP device"
70 + description: |
71 + Before configuring the collector:
72 + - Enable the SNMP service on the target device (through its management interface).
73 + - Make sure the device is reachable from the Netdata node on port 161/UDP.
74 + - Have ready the required connection details: IP address, SNMP version, and either a community string (v1/v2c) or user credentials (v3).
75 configuration:
76 file:
77 name: go.d/snmp.conf
@@ -85,7 +91,7 @@ modules:
91 default_value: 0
92 required: false
93 - name: hostname
88 - description: Target ipv4 address.
94 + description: Target host (IP or DNS name, IPv4/IPv6).
95 default_value: ""
96 required: true
97 - name: enable_profiles
@@ -93,7 +99,7 @@ modules:
99 default_value: "true"
100 required: false
101 - name: enable_profiles_table_metrics
96 - description: Enable collection of SNMP table metrics from profiles. Enabling this may **increase collection time and memory usage** for devices with many network interfaces*.
102 + description: Enable collection of SNMP table metrics from profiles. Enabling this may **increase collection time and memory usage** for devices with many network interfaces.
103 default_value: "true"
104 required: false
105 - name: disable_legacy_collection
@@ -160,11 +166,7 @@ modules:
166 description: SNMPv3 user name.
167 default_value: ""
168 required: false
163 - - name: user.name
164 - description: Security level of SNMPv3 messages.
165 - default_value: ""
166 - required: false
167 - - name: user.auth_proto
169 + - name: user.level
170 description: Security level of SNMPv3 messages.
171 default_value: ""
172 required: false
@@ -176,7 +178,7 @@ modules:
178 | none | 1 | no message authentication or encryption |
179 | authNoPriv | 2 | message authentication and no encryption |
180 | authPriv | 3 | message authentication and encryption |
179 - - name: user.name
181 + - name: user.auth_proto
182 description: Authentication protocol for SNMPv3 messages.
183 default_value: ""
184 required: false
@@ -193,7 +195,7 @@ modules:
195 | sha384 | 6 | SHA message authentication (HMAC-SHA-384) |
196 | sha512 | 7 | SHA message authentication (HMAC-SHA-512) |
197 - name: user.auth_key
196 - description: Authentication protocol pass phrase.
198 + description: Authentication protocol pass phrase for SNMPv3 messages.
199 default_value: ""
200 required: false
201 - name: user.priv_proto
@@ -213,7 +215,7 @@ modules:
215 | aes192c | 6 | 192-bit AES encryption (CFB-AES-192) with "Reeder" key localization |
216 | aes256c | 7 | 256-bit AES encryption (CFB-AES-256) with "Reeder" key localization |
217 - name: user.priv_key
216 - description: Privacy protocol pass phrase.
218 + description: Privacy protocol pass phrase for SNMPv3 messages.
219 default_value: ""
220 required: false
221 examples: