use monotonic clock for logs flooding detection
This avoids incorrect flood detection on system time changes or system hibernation/suspend. Signed-off-by: Rémi Lefèvre <remi.lefevre@parrot.com>
Rémi Lefèvre committed
Dec 9, 2016 at 09:54 UTC
b99c76d78e0038c184c76815a68bf8846f574b4c
1 file changed
+1
-1
src/log.c
+1
-1
@@ -131,7 +131,7 @@ int error_log_limit(int reset) {
131
return 1;
132
#endif
133
134
- time_t now = now_realtime_sec();
134
+ time_t now = now_monotonic_sec();
135
if(!start) start = now;
136
137
if(reset) {