SNMP: avocent profile (#20527)
Co-authored-by: ilyam8 <ilya@netdata.cloud>
Fotis Voutsas committed
Jun 29, 2025 at 18:06 UTC
2e93fa650f4da93c9d1d6a73b6b16babc90f9179
1 file changed
+41
-46
src/go/plugin/go.d/config/go.d/snmp.profiles/default/avocent-acs.yaml
+41
-46
@@ -3,6 +3,14 @@ extends:
3
- _generic-if.yaml
4
- _generic-ucd.yaml
5
6
+metadata:
7
+ device:
8
+ fields:
9
+ vendor:
10
+ value: Avocent
11
+ type:
12
+ value: Console Server
13
+
14
sysobjectid:
15
- 1.3.6.1.4.1.10418.26.1.* # Avocent Console Server
16
- 1.3.6.1.4.1.10418.26.1.1 # Avocent acs8048
@@ -13,69 +21,56 @@ sysobjectid:
21
- 1.3.6.1.4.1.10418.26.1.6 # Avocent acs804
22
- 1.3.6.1.4.1.10418.26.1.7 # Avocent acs802
23
16
-metadata:
17
- device:
18
- fields:
19
- vendor:
20
- value: "avocent"
21
-
24
metrics:
23
-# - MIB: ACS8000-MIB
24
-# symbol:
25
-# name: avocent.acsPowerSupplyStatePw1
26
-# OID: 1.3.6.1.4.1.10418.26.2.1.8.2.0
27
-# enum:
28
-# statePowerOn: 1
29
-# statePowerOff: 2
30
-# powerNotInstaled: 9999
31
-# TODO: enum in scalar metric is not supported yet (keep this metric and this
32
-# comment in profile until it's fixed)
33
-# - MIB: ACS8000-MIB
34
-# symbol:
35
-# name: avocent.acsPowerSupplyStatePw2
36
-# OID: 1.3.6.1.4.1.10418.26.2.1.8.3.0
37
-# enum:
38
-# statePowerOn: 1
39
-# statePowerOff: 2
40
-# powerNotInstaled: 9999
41
-# TODO: enum in scalar metric is not supported yet (keep this metric and this
42
-# comment in profile until it's fixed)
25
+ - MIB: ACS8000-MIB
26
+ symbol:
27
+ name: avocent.acsPowerSupplyStatePw1
28
+ OID: 1.3.6.1.4.1.10418.26.2.1.8.2.0
29
+ description: State of the first power supply
30
+ family: PowerSupply/1/Status
31
+ unit: "{status}"
32
+ mapping:
33
+ statePowerOn: 1
34
+ statePowerOff: 2
35
+ powerNotInstaled: 9999
36
+ - MIB: ACS8000-MIB
37
+ symbol:
38
+ name: avocent.acsPowerSupplyStatePw2
39
+ OID: 1.3.6.1.4.1.10418.26.2.1.8.3.0
40
+ description: State of the second power supply
41
+ family: PowerSupply/2/Status
42
+ unit: "{status}"
43
+ mapping:
44
+ statePowerOn: 1
45
+ statePowerOff: 2
46
+ powerNotInstaled: 9999
47
- MIB: ACS8000-MIB
48
symbol:
49
name: avocent.acsActiveSessionsNumberOfSession
50
OID: 1.3.6.1.4.1.10418.26.2.2.1.0
47
- description: Number of active sessions.
51
+ description: Number of active sessions
52
+ family: Session/Active
53
unit: "{session}"
54
- MIB: ACS8000-MIB
55
table:
56
OID: 1.3.6.1.4.1.10418.26.2.3.2
57
name: acsSerialPortTable
58
symbols:
54
- - name: avocent.acsSerialPort
55
- constant_value_one: true
56
- description: Serial port constant value one.
57
- unit: "TBD"
58
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
59
+ - OID: 1.3.6.1.4.1.10418.26.2.3.2.1.3
60
+ name: avocent.acsSerialPortTableStatus
61
+ description: The status of the serial port
62
+ family: SerialPort/Status
63
+ unit: "{status}"
64
+ mapping:
65
+ 1: disabled
66
+ 2: idle
67
+ 3: in_use
68
metric_tags:
69
- tag: avocent_acs_serial_port_table_device_name
70
symbol:
71
name: avocent.acsSerialPortTableDeviceName
72
OID: 1.3.6.1.4.1.10418.26.2.3.2.1.2
64
- description: The associated device name for the serial port.
65
- unit: "TBD"
73
- tag: avocent_acs_serial_port_table_name
74
symbol:
75
name: avocent.acsSerialPortTableName
76
OID: 1.3.6.1.4.1.10418.26.2.3.2.1.4
70
- description: Name associated with this serial port.
71
- unit: "TBD"