chore(go.d/snmp-profiles): charts meta fixes and fam updates p1 (#20620)
Ilya Mashchenko committed
Jul 1, 2025 at 18:56 UTC
91e743708d99a79184b2352532d2ffd75fc95893
10 files changed
+409
-397
src/go/plugin/go.d/config/go.d/snmp.profiles/default/tp-link.yaml
+17
-16
@@ -2,15 +2,16 @@ extends:
2
- _system-base.yaml
3
- _std-if-mib.yaml
4
5
+sysobjectid:
6
+ - 1.3.6.1.4.1.11863.1.* # TP-Link switch
7
+ - 1.3.6.1.4.1.11863.5.* # TP-Link products
8
+
9
metadata:
10
device:
11
fields:
12
vendor:
13
value: "TP-Link"
14
11
-sysobjectid:
12
- - 1.3.6.1.4.1.11863.1.* # TP-Link switch
13
- - 1.3.6.1.4.1.11863.5.* # TP-Link products
15
metrics:
16
- MIB: TPLINK-SYSMONITOR-MIB
17
table:
@@ -19,16 +20,14 @@ metrics:
20
symbols:
21
- name: cpu.usage
22
OID: 1.3.6.1.4.1.11863.6.4.1.1.1.1.3
22
- description: CPU utilization in 1 minute
23
- unit: "%"
24
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
23
+ chart_meta:
24
+ description: CPU utilization in 1 minute
25
+ family: CPU/Usage
26
+ unit: "%"
27
metric_tags:
26
- - symbol:
27
- OID: 1.3.6.1.4.1.11863.6.4.1.1.1.1.4
28
- name: tpSysMonitorCpu5Minutes
29
- tag: tp_sys_monitor_cpu_5_minutes
30
- - index: 1 # tpSysMonitorCpuUnitNumber
31
- tag: cpu
28
+ - tag: cpu_index
29
+ index: 1 # tpSysMonitorCpuUnitNumber
30
+
31
- MIB: TPLINK-SYSMONITOR-MIB
32
table:
33
name: tpSysMonitorMemoryTable
@@ -36,8 +35,10 @@ metrics:
35
symbols:
36
- name: memory.usage
37
OID: 1.3.6.1.4.1.11863.6.4.1.2.1.1.2
39
- description: Memory utilization
40
- unit: "%"
38
+ chart_meta:
39
+ description: Memory utilization
40
+ family: Memory/Usage
41
+ unit: "%"
42
metric_tags:
42
- - index: 1 # tpSysMonitorMemoryUnitNumber
43
- tag: mem
43
+ - tag: mem_index
44
+ index: 1 # tpSysMonitorMemoryUnitNumber
src/go/plugin/go.d/config/go.d/snmp.profiles/default/ubiquiti-unifi-security-gateway.yaml
+1
@@ -2,5 +2,6 @@ extends:
2
- _std-if-mib.yaml
3
- _std-ucd-mib.yaml
4
- _ubiquiti.yaml
5
+
6
sysobjectid:
7
- 1.3.6.1.4.1.41112.1.5 # Ubiquiti EdgeMax
src/go/plugin/go.d/config/go.d/snmp.profiles/default/ubiquiti-unifi.yaml
+41
-41
@@ -10,31 +10,21 @@ metrics:
10
symbol:
11
OID: 1.3.6.1.4.1.10002.1.1.1.1.1.0
12
name: memory.total
13
- description: Total usable physical memory (in KB)
14
- unit: "kBy"
13
+ scale_factor: 1024
14
+ chart_meta:
15
+ description: Total usable physical memory (in KB)
16
+ family: Memory/Total
17
+ unit: "By"
18
- MIB: FROGFOOT-RESOURCES-MIB
19
symbol:
20
OID: 1.3.6.1.4.1.10002.1.1.1.1.2.0
21
name: memory.free
19
- description: Available physical memory (in KB)
20
- unit: "kBy"
21
- # TODO: Update once we support matching on specific tag (`match_attributes`)
22
- # - MIB: FROGFOOT-RESOURCES-MIB
23
- # table:
24
- # OID: 1.3.6.1.4.1.10002.1.1.1.4.2
25
- # name: loadTable
26
- # symbols:
27
- # - OID: 1.3.6.1.4.1.10002.1.1.1.4.2.1.3.1
28
- # name: cpu.usage
29
- # metric_tags:
30
- # - index: 1
31
- # tag: cpu
32
- # - symbol:
33
- # OID: 1.3.6.1.4.1.10002.1.1.1.4.2.1.2.1
34
- # name: loadDescr
35
- # match_attributes:
36
- # - 1 Minute Average
37
- # tag: load_descr
22
+ scale_factor: 1024
23
+ chart_meta:
24
+ description: Available physical memory (in KB)
25
+ family: Memory/Free
26
+ unit: "By"
27
+
28
- MIB: UBNT-UniFi-MIB
29
table:
30
OID: 1.3.6.1.4.1.41112.1.6.1.1
@@ -42,40 +32,50 @@ metrics:
32
symbols:
33
- OID: 1.3.6.1.4.1.41112.1.6.1.1.1.4
34
name: ubiquiti.unifiRadioRxPackets
45
- metric_type: monotonic_count
46
- description: Number of received packets on the radio
47
- unit: "{packet}"
35
+ chart_meta:
36
+ description: Number of received packets on the radio
37
+ family: Wireless/Radio/Packet/In
38
+ unit: "{packet}/s"
39
- OID: 1.3.6.1.4.1.41112.1.6.1.1.1.5
40
name: ubiquiti.unifiRadioTxPackets
50
- metric_type: monotonic_count
51
- description: Number of transmitted packets on the radio
52
- unit: "{packet}"
41
+ chart_meta:
42
+ description: Number of transmitted packets on the radio
43
+ family: Wireless/Radio/Packet/Out
44
+ unit: "{packet}/s"
45
- OID: 1.3.6.1.4.1.41112.1.6.1.1.1.6
46
name: ubiquiti.unifiRadioCuTotal
55
- description: Total cumulative usage on the radio
56
- unit: "TBD"
47
+ chart_meta:
48
+ description: Total channel utilization on the radio
49
+ family: Wireless/Radio/ChannelUtilization/Total
50
+ unit: "%"
51
- OID: 1.3.6.1.4.1.41112.1.6.1.1.1.7
52
name: ubiquiti.unifiRadioCuSelfRx
59
- description: Cumulative self received usage on the radio
60
- unit: "TBD"
53
+ chart_meta:
54
+ description: Channel utilization for self received traffic on the radio
55
+ family: Wireless/Radio/ChannelUtilization/SelfReceive
56
+ unit: "%"
57
- OID: 1.3.6.1.4.1.41112.1.6.1.1.1.8
58
name: ubiquiti.unifiRadioCuSelfTx
63
- description: Cumulative self transmitted usage on the radio
64
- unit: "TBD"
59
+ chart_meta:
60
+ description: Channel utilization for self transmitted traffic on the radio
61
+ family: Wireless/Radio/ChannelUtilization/SelfTransmit
62
+ unit: "%"
63
- OID: 1.3.6.1.4.1.41112.1.6.1.1.1.9
64
name: ubiquiti.unifiRadioOtherBss
67
- description: Other basic service sets on the radio
68
- unit: "TBD"
65
+ chart_meta:
66
+ description: Number of other basic service sets detected on the radio
67
+ family: Wireless/Radio/BSS/Other/Count
68
+ unit: "{bss}"
69
metric_tags:
70
- - symbol:
70
+ - tag: ubiquiti_unifi_radio_index
71
+ symbol:
72
OID: 1.3.6.1.4.1.41112.1.6.1.1.1.1
73
name: ubiquiti.unifiRadioIndex
73
- tag: ubiquiti_unifi_radio_index
74
- - symbol:
74
+ - tag: ubiquiti_unifi_radio_name
75
+ symbol:
76
OID: 1.3.6.1.4.1.41112.1.6.1.1.1.2
77
name: ubiquiti.unifiRadioName
77
- tag: ubiquiti_unifi_radio_name
78
- - symbol:
78
+ - tag: ubiquiti_unifi_radio_radio
79
+ symbol:
80
OID: 1.3.6.1.4.1.41112.1.6.1.1.1.3
81
name: ubiquiti.unifiRadioRadio
81
- tag: ubiquiti_unifi_radio_radio
src/go/plugin/go.d/config/go.d/snmp.profiles/default/velocloud-edge.yaml
-19
@@ -13,22 +13,3 @@ metadata:
13
14
sysobjectid:
15
- 1.3.6.1.4.1.45346.1.1 # VeloCloud EDGE
16
-metrics:
17
- - MIB: HOST-RESOURCES-MIB
18
- symbol:
19
- name: memory.total
20
- OID: 1.3.6.1.2.1.25.2.3.1.5.1 # hrStorageSize.1
21
- description: Size of the storage represented by this entry, in units of hrStorageAllocationUnits
22
- unit: "{storage_unit}"
23
- - MIB: HOST-RESOURCES-MIB
24
- symbol:
25
- name: memory.used
26
- OID: 1.3.6.1.2.1.25.2.3.1.6.1 # hrStorageUsed.1
27
- description: Amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits
28
- unit: "{storage_unit}"
29
- - MIB: HOST-RESOURCES-MIB
30
- symbol:
31
- name: cpu.usage
32
- OID: 1.3.6.1.2.1.25.3.3.1.2.196608 # hrProcessorLoad.196608
33
- description: Average over the last minute of the percentage of time that this processor was not idle
34
- unit: "%"
src/go/plugin/go.d/config/go.d/snmp.profiles/default/vertiv-liebert-ac.yaml
+69
-33
@@ -1,20 +1,36 @@
1
extends:
2
- _vertiv.yaml
3
+
4
sysobjectid:
5
- 1.3.6.1.4.1.476.1.42 # liebertGlobalProducts
6
+
7
+metric_tags:
8
+ - tag: lgp_agent_ident_model
9
+ OID: 1.3.6.1.4.1.476.1.42.2.1.2.0
10
+ symbol: lgpAgentIdentModel
11
+ - tag: lgp_agent_ident_serial_number
12
+ OID: 1.3.6.1.4.1.476.1.42.2.1.4.0
13
+ symbol: lgpAgentIdentSerialNumber
14
+
15
metrics:
16
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
17
symbol:
18
OID: 1.3.6.1.4.1.476.1.42.3.4.1.2.1.0
19
name: lgpEnvTemperatureSettingDegF
10
- description: The temperature setting used to control the well known temperature object 'lgpEnvControlTemperature'
11
- unit: "degF"
20
+ chart_meta:
21
+ description: The temperature setting used to control the well known temperature object lgpEnvControlTemperature
22
+ family: Environment/Temperature/Setpoint
23
+ unit: "degF"
24
+
25
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
26
symbol:
27
OID: 1.3.6.1.4.1.476.1.42.3.4.1.2.2.0
28
name: lgpEnvTemperatureToleranceDegF
16
- description: The acceptable variance from 'lgpEnvTemperatureSettingDegF' without initiating a control action
17
- unit: "degF"
29
+ chart_meta:
30
+ description: The acceptable variance from lgpEnvTemperatureSettingDegF without initiating a control action
31
+ family: Environment/Temperature/Tolerance
32
+ unit: "degF"
33
+
34
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
35
table:
36
OID: 1.3.6.1.4.1.476.1.42.3.4.1.2.3
@@ -22,67 +38,87 @@ metrics:
38
symbols:
39
- OID: 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.3
40
name: lgpEnvTemperatureMeasurementDegF
25
- description: The measured temperature value
26
- unit: "degF"
41
+ chart_meta:
42
+ description: The measured temperature value
43
+ family: Environment/Temperature/Value
44
+ unit: "degF"
45
- OID: 1.3.6.1.4.1.476.1.42.3.4.1.3.3.1.3
46
name: lgpEnvTemperatureMeasurementDegC
29
- description: The measured temperature value
30
- unit: "Cel"
47
+ chart_meta:
48
+ description: The measured temperature value
49
+ family: Environment/Temperature/Value
50
+ unit: "Cel"
51
- OID: 1.3.6.1.4.1.476.1.42.3.4.2.2.3.1.3
52
name: lgpEnvHumidityMeasurementRel
33
- description: The measured humidity value
34
- unit: "%"
53
+ chart_meta:
54
+ description: The measured humidity value
55
+ family: Environment/Humidity/Value
56
+ unit: "%"
57
metric_tags:
36
- - symbol:
58
+ - tag: lgp_env_temperature_descr_deg_f
59
+ symbol:
60
OID: 1.3.6.1.4.1.476.1.42.3.4.1.2.3.1.2 # OID index
61
name: lgpEnvTemperatureDescrDegF
39
- tag: lgp_env_temperature_descr_deg_f
62
+
63
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
64
symbol:
65
OID: 1.3.6.1.4.1.476.1.42.3.4.6.1.0
66
name: lgpEnvStatisticsComp1RunHr
44
- description: Accumulated run hours of compressor 1
45
- unit: "h"
67
+ chart_meta:
68
+ description: Accumulated run hours of compressor 1
69
+ family: Component/Compressor/1/Runtime
70
+ unit: "h"
71
+
72
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
73
symbol:
74
OID: 1.3.6.1.4.1.476.1.42.3.4.6.2.0
75
name: lgpEnvStatisticsComp2RunHr
50
- description: Accumulated run hours of compressor 2
51
- unit: "h"
76
+ chart_meta:
77
+ description: Accumulated run hours of compressor 2
78
+ family: Component/Compressor/2/Runtime
79
+ unit: "h"
80
+
81
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
82
symbol:
83
OID: 1.3.6.1.4.1.476.1.42.3.4.6.3.0
84
name: lgpEnvStatisticsFanRunHr
56
- description: Accumulated run hours of the main fan
57
- unit: "h"
85
+ chart_meta:
86
+ description: Accumulated run hours of the main fan
87
+ family: Component/Fan/Runtime
88
+ unit: "h"
89
+
90
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
91
symbol:
92
OID: 1.3.6.1.4.1.476.1.42.3.4.6.4.0
93
name: lgpEnvStatisticsHumRunHr
62
- description: Accumulated run hours of the humidifier
63
- unit: "h"
94
+ chart_meta:
95
+ description: Accumulated run hours of the humidifier
96
+ family: Component/Humidifier/Runtime
97
+ unit: "h"
98
+
99
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
100
symbol:
101
OID: 1.3.6.1.4.1.476.1.42.3.4.6.7.0
102
name: lgpEnvStatisticsReheat1RunHr
68
- description: Accumulated run hours of reheat element 1
69
- unit: "h"
103
+ chart_meta:
104
+ description: Accumulated run hours of reheat element 1
105
+ family: Component/Reheat/1/Runtime
106
+ unit: "h"
107
+
108
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
109
symbol:
110
OID: 1.3.6.1.4.1.476.1.42.3.4.6.8.0
111
name: lgpEnvStatisticsReheat2RunHr
74
- description: Accumulated run hours of reheat element 2
75
- unit: "h"
112
+ chart_meta:
113
+ description: Accumulated run hours of reheat element 2
114
+ family: Component/Reheat/2/Runtime
115
+ unit: "h"
116
+
117
- MIB: LIEBERT-GP-ENVIRONMENTAL-MIB
118
symbol:
119
OID: 1.3.6.1.4.1.476.1.42.3.4.6.9.0
120
name: lgpEnvStatisticsReheat3RunHr
80
- description: Accumulated run hours of reheat element 3
81
- unit: "h"
82
-metric_tags:
83
- - tag: lgp_agent_ident_model
84
- OID: 1.3.6.1.4.1.476.1.42.2.1.2.0
85
- symbol: lgpAgentIdentModel
86
- - tag: lgp_agent_ident_serial_number
87
- OID: 1.3.6.1.4.1.476.1.42.2.1.4.0
88
- symbol: lgpAgentIdentSerialNumber
121
+ chart_meta:
122
+ description: Accumulated run hours of reheat element 3
123
+ family: Component/Reheat/3/Runtime
124
+ unit: "h"
src/go/plugin/go.d/config/go.d/snmp.profiles/default/vertiv-watchdog.yaml
+63
-54
@@ -1,12 +1,29 @@
1
extends:
2
- _vertiv.yaml
3
+
4
sysobjectid:
5
- 1.3.6.1.4.1.21239.5.1 # watchdog100
6
+
7
metadata:
8
device:
9
fields:
10
type:
11
value: "sensor"
12
+
13
+metric_tags:
14
+ - tag: vertiv_product_title
15
+ OID: 1.3.6.1.4.1.21239.5.1.1.1.0
16
+ symbol: productTitle
17
+ - tag: vertiv_product_version
18
+ OID: 1.3.6.1.4.1.21239.5.1.1.2.0
19
+ symbol: productVersion
20
+ - tag: vertiv_product_friendly_name
21
+ OID: 1.3.6.1.4.1.21239.5.1.1.3.0
22
+ symbol: productFriendlyName
23
+ - tag: vertiv_product_mac_address
24
+ OID: 1.3.6.1.4.1.21239.5.1.1.4.0
25
+ symbol: productMacAddress
26
+
27
metrics:
28
- MIB: VERTIV-BB-MIB
29
table:
@@ -15,39 +32,40 @@ metrics:
32
symbols:
33
- OID: 1.3.6.1.4.1.21239.5.1.2.1.5
34
name: vertiv.internalTemp
18
- description: Internal temperature measurement
19
- unit: "Cel"
35
+ chart_meta:
36
+ description: Internal temperature measurement
37
+ family: Sensor/Temperature/Value
38
+ unit: "Cel"
39
- OID: 1.3.6.1.4.1.21239.5.1.2.1.6
40
name: vertiv.internalHumidity
22
- description: Internal humidity measurement
23
- unit: "%"
41
+ chart_meta:
42
+ description: Internal humidity measurement
43
+ family: Sensor/Humidity/Value
44
+ unit: "%"
45
- OID: 1.3.6.1.4.1.21239.5.1.2.1.7
46
name: vertiv.internalDewPoint
26
- description: Internal dew point temperature
27
- unit: "Cel"
28
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
29
- metric_tags:
30
- - symbol:
31
- OID: 1.3.6.1.4.1.21239.5.1.2.1.2
32
- name: vertiv.internalSerial
33
- tag: vertiv_internal_serial
34
- # - symbol:
35
- # OID: 1.3.6.1.4.1.21239.5.1.1.7.0
36
- # name: vertiv.temperatureUnits
37
- # tag: vertiv_temperature_units
38
- # mapping:
39
- # 0: fahrenheit
40
- # 1: celsius
41
- # TODO : Add this tag back when tagging by scalar symbol is implemented NDM-2247
42
- - symbol:
43
- OID: 1.3.6.1.4.1.21239.5.1.2.1.4
44
- name: vertiv.internalAvail
45
- tag: vertiv_internal_avail
47
+ chart_meta:
48
+ description: Internal dew point temperature
49
+ family: Sensor/DewPoint/Value
50
+ unit: "Cel"
51
+ - OID: 1.3.6.1.4.1.21239.5.1.2.1.4
52
+ name: vertiv.internalAvail
53
+ chart_meta:
54
+ description: Internal availability status
55
+ family: Sensor/Availability/Status
56
+ unit: "{status}"
57
mapping:
58
0: unavailable
59
1: available
60
2: partially_unavailable
50
- # mapping in the metric description
61
+ metric_tags:
62
+ - tag: vertiv_internal_index
63
+ index: 1
64
+ - tag: vertiv_internal_serial
65
+ symbol:
66
+ OID: 1.3.6.1.4.1.21239.5.1.2.1.2
67
+ name: vertiv.internalSerial
68
+
69
- MIB: VERTIV-BB-MIB
70
table:
71
name: tempSensorTable
@@ -55,37 +73,28 @@ metrics:
73
symbols:
74
- OID: 1.3.6.1.4.1.21239.5.1.4.1.5
75
name: vertiv.tempSensorTemp
58
- description: Temperature measured by the temperature sensor
59
- unit: "Cel"
60
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
76
+ chart_meta:
77
+ description: Temperature measured by the temperature sensor
78
+ family: Sensor/Temperature/Value
79
+ unit: "Cel"
80
+ - OID: 1.3.6.1.4.1.21239.5.1.4.1.4
81
+ name: vertiv.tempSensorAvail
82
+ chart_meta:
83
+ description: Sensor availability status
84
+ family: Sensor/Availability/Status
85
+ unit: "{status}"
86
+ mapping:
87
+ 0: unavailable
88
+ 1: available
89
+ 2: partially_unavailable
90
metric_tags:
62
- - symbol:
91
+ - tag: vertiv_sensor_index
92
+ index: 1
93
+ - tag: vertiv_temp_sensor_serial
94
+ symbol:
95
OID: 1.3.6.1.4.1.21239.5.1.4.1.2
96
name: vertiv.tempSensorSerial
65
- tag: vertiv_temp_sensor_serial
66
- - symbol:
97
+ - tag: vertiv_temp_sensor_label
98
+ symbol:
99
OID: 1.3.6.1.4.1.21239.5.1.4.1.3
100
name: vertiv.tempSensorLabel
69
- tag: vertiv_temp_sensor_label
70
- - symbol:
71
- OID: 1.3.6.1.4.1.21239.5.1.4.1.4
72
- name: vertiv.tempSensorAvail
73
- tag: vertiv_temp_sensor_avail
74
- mapping:
75
- 0: unavailable
76
- 1: available
77
- 2: partially_unavailable
78
- # mapping in the metric description
79
-metric_tags:
80
- - OID: 1.3.6.1.4.1.21239.5.1.1.1.0
81
- symbol: productTitle
82
- tag: vertiv_product_title
83
- - OID: 1.3.6.1.4.1.21239.5.1.1.2.0
84
- symbol: productVersion
85
- tag: vertiv_product_version
86
- - OID: 1.3.6.1.4.1.21239.5.1.1.3.0
87
- symbol: productFriendlyName
88
- tag: vertiv_product_friendly_name
89
- - OID: 1.3.6.1.4.1.21239.5.1.1.4.0
90
- symbol: productMacAddress
91
- tag: vertiv_product_mac_address
src/go/plugin/go.d/config/go.d/snmp.profiles/default/vmware-esx.yaml
+31
-34
@@ -3,6 +3,9 @@ extends:
3
- _std-host-resources-mib-feat-base.yaml
4
- _std-if-mib.yaml
5
6
+sysobjectid:
7
+ - 1.3.6.1.4.1.6876.4.1
8
+
9
metadata:
10
device:
11
fields:
@@ -11,50 +14,54 @@ metadata:
14
type:
15
value: "server"
16
14
-sysobjectid:
15
- - 1.3.6.1.4.1.6876.4.1
16
-
17
metrics:
18
- MIB: VMWARE-RESOURCES-MIB
19
table:
20
OID: 1.3.6.1.4.1.6876.3.5.2
21
name: vmwHostBusAdapterTable
22
symbols:
23
- - name: vmwHostBusAdapter
24
- constant_value_one: true
25
- description: "Hardware host bus adapter"
26
- unit: "{hardware_host_bus_adapter}"
27
- metric_tags:
28
- - symbol:
29
- name: vmwHbaDeviceName
30
- OID: 1.3.6.1.4.1.6876.3.5.2.1.2
31
- tag: vmw_hba_device_name
32
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
33
- - symbol:
34
- OID: 1.3.6.1.4.1.6876.3.5.2.1.4
35
- name: vmwHbaStatus
36
- tag: vmw_hba_status
23
+ - OID: 1.3.6.1.4.1.6876.3.5.2.1.4
24
+ name: vmwHbaStatus
25
+ chart_meta:
26
+ description: Current HBA status
27
+ family: Storage/HBA/Status
28
+ unit: "{status}"
29
mapping:
30
1: unknown
31
2: normal
32
3: marginal
33
4: critical
34
5: failed
35
+ metric_tags:
36
+ - tag: vmw_hba_device_name
37
+ symbol:
38
+ name: vmwHbaDeviceName
39
+ OID: 1.3.6.1.4.1.6876.3.5.2.1.2
40
+
41
- MIB: VMWARE-ENV-MIB
42
table:
43
OID: 1.3.6.1.4.1.6876.4.20.3
44
name: vmwEnvTable
45
symbols:
48
- - name: vmwEnv
49
- constant_value_one: true
50
- description: "Hardware environment"
51
- unit: "{hardware_environment}"
52
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
46
+ - OID: 1.3.6.1.4.1.6876.4.20.3.1.3
47
+ name: vmwHardwareStatus
48
+ chart_meta:
49
+ description: Last reported status of this component
50
+ family: Hardware/Component/Status
51
+ unit: "{status}"
52
+ mapping:
53
+ 1: unknown
54
+ 2: normal
55
+ 3: marginal
56
+ 4: critical
57
+ 5: failed
58
metric_tags:
54
- - symbol:
59
+ - tag: vmw_subsystem_index
60
+ index: 1
61
+ - tag: vmw_subsystem_type
62
+ symbol:
63
name: vmwSubsystemType
64
OID: 1.3.6.1.4.1.6876.4.20.3.1.2
57
- tag: vmw_subsystem_type
65
mapping:
66
1: unknown
67
2: chassis
@@ -66,13 +73,3 @@ metrics:
73
8: temperature_sensor
74
9: raid_controller
75
10: voltage
69
- - symbol:
70
- OID: 1.3.6.1.4.1.6876.4.20.3.1.3
71
- name: vmwHardwareStatus
72
- tag: vmw_hardware_status
73
- mapping:
74
- 1: unknown
75
- 2: normal
76
- 3: marginal
77
- 4: critical
78
- 5: failed
src/go/plugin/go.d/config/go.d/snmp.profiles/default/western-digital-mycloud-ex2-ultra.yaml
+113
-133
@@ -3,6 +3,9 @@ extends:
3
- _std-host-resources-mib-feat-base.yaml
4
- _std-if-mib.yaml
5
6
+sysobjectid:
7
+ - 1.3.6.1.4.1.5127.1.1.1.8
8
+
9
metadata:
10
device:
11
fields:
@@ -11,31 +14,31 @@ metadata:
14
type:
15
value: "storage"
16
14
-sysobjectid:
15
- - 1.3.6.1.4.1.5127.1.1.1.8
17
+metric_tags:
18
+ - tag: wdmycloudex2_agent_ver
19
+ OID: 1.3.6.1.4.1.5127.1.1.1.8.1.1.0
20
+ symbol: wdmycloudex2AgentVer
21
+ - tag: wdmycloudex2_software_version
22
+ OID: 1.3.6.1.4.1.5127.1.1.1.8.1.2.0
23
+ symbol: wdmycloudex2SoftwareVersion
24
+ - tag: wdmycloudex2_host_name
25
+ OID: 1.3.6.1.4.1.5127.1.1.1.8.1.3.0
26
+ symbol: wdmycloudex2HostName
27
+ - tag: wdmycloudex2_ftp_server
28
+ OID: 1.3.6.1.4.1.5127.1.1.1.8.1.5.0
29
+ symbol: wdmycloudex2FTPServer
30
+ mapping:
31
+ 0: disable
32
+ 1: enable
33
+ - tag: wdmycloudex2_net_type
34
+ OID: 1.3.6.1.4.1.5127.1.1.1.8.1.6.0
35
+ symbol: wdmycloudex2NetType
36
+ mapping:
37
+ 0: workgroup
38
+ 1: active_directory
39
40
+# TODO: add metrics, need snmpwalk sample
41
metrics:
18
- - MIB: HOST-RESOURCES-MIB
19
- symbol:
20
- name: memory.total
21
- OID: 1.3.6.1.2.1.25.2.3.1.5.1 # hrStorageSize.1
22
- description: Size of the storage represented by this entry, in units of hrStorageAllocationUnits
23
- unit: "{logical_storage_area}"
24
-
25
- - MIB: HOST-RESOURCES-MIB
26
- symbol:
27
- name: memory.used
28
- OID: 1.3.6.1.2.1.25.2.3.1.6.1 # hrStorageUsed.1
29
- description: Amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits
30
- unit: "{logical_storage_area}"
31
-
32
- - MIB: HOST-RESOURCES-MIB
33
- symbol:
34
- name: cpu.usage
35
- OID: 1.3.6.1.2.1.25.3.3.1.2.196608 # hrProcessorLoad.196608
36
- description: Average over the last minute of the percentage of time that this processor was not idle
37
- unit: "%"
38
-
42
# - MIB: WDMYCLOUDEX2-MIB
43
# symbol:
44
# name: wdmycloudex2Temperature
@@ -46,120 +49,97 @@ metrics:
49
# name: wdmycloudex2FanStatus
50
# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.8.0
51
# string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
49
- - MIB: WDMYCLOUDEX2-MIB
50
- table:
51
- name: wdmycloudex2VolumeTable
52
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9
53
- symbols:
54
- - name: wdmycloudex2Volume
55
- constant_value_one: true
52
+# - MIB: WDMYCLOUDEX2-MIB
53
+# table:
54
+# name: wdmycloudex2VolumeTable
55
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9
56
+# symbols:
57
+# - name: wdmycloudex2Volume
58
+# constant_value_one: true
59
# - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.5
60
# name: wdmycloudex2VolumeSize
61
# string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
62
# - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.6
63
# name: wdmycloudex2VolumeFreeSpace
64
# string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
62
- metric_tags:
63
- - symbol:
64
- name: wdmycloudex2VolumeNum
65
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.1
66
- tag: wdmycloudex2_volume_num
67
- - symbol:
68
- name: wdmycloudex2VolumeName
69
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.2
70
- tag: wdmycloudex2_volume_name
71
- - symbol:
72
- name: wdmycloudex2VolumeFsType
73
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.3
74
- tag: wdmycloudex2_volume_fs_type
75
- - symbol:
76
- name: wdmycloudex2VolumeRaidLevel
77
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.4
78
- tag: wdmycloudex2_volume_raid_level
79
- - MIB: WDMYCLOUDEX2-MIB
80
- table:
81
- name: wdmycloudex2DiskTable
82
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10
83
- symbols:
84
-# - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.5
85
-# name: wdmycloudex2DiskTemperature
86
-# string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
87
- - name: wdmycloudex2Disk
88
- constant_value_one: true
89
- metric_tags:
90
- - symbol:
91
- name: wdmycloudex2DiskNum
92
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.1
93
- tag: wdmycloudex2_disk_num
94
- - symbol:
95
- name: wdmycloudex2DiskVendor
96
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.2
97
- tag: wdmycloudex2_disk_vendor
98
- - symbol:
99
- name: wdmycloudex2DiskModel
100
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.3
101
- tag: wdmycloudex2_disk_model
102
- - symbol:
103
- name: wdmycloudex2DiskSerialNumber
104
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.4
105
- tag: wdmycloudex2_disk_serial_number
106
- - symbol:
107
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.6
108
- name: wdmycloudex2DiskCapacity
109
- tag: wdmycloudex2_disk_capacity
110
- - MIB: WDMYCLOUDEX2-MIB
111
- table:
112
- name: wdmycloudex2UPSTable
113
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11
114
- symbols:
115
- - name: wdmycloudex2UPS
116
- constant_value_one: true
117
-# - name: wdmycloudex2UPSBatteryCharge
118
-# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.5
119
-# string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
120
- metric_tags:
121
- - symbol:
122
- name: wdmycloudex2UPSNum
123
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.1
124
- tag: wdmycloudex2_ups_num
125
- - symbol:
126
- name: wdmycloudex2UPSMode
127
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.2
128
- tag: wdmycloudex2_ups_mode
129
- - symbol:
130
- name: wdmycloudex2UPSManufacturer
131
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.3
132
- tag: wdmycloudex2_ups_manufacturer
133
- - symbol:
134
- name: wdmycloudex2UPSProduct
135
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.4
136
- tag: wdmycloudex2_ups_product
137
- - symbol:
138
- name: wdmycloudex2UPSStatus
139
- OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.6
140
- tag: wdmycloudex2_ups_status
65
+# metric_tags:
66
+# - symbol:
67
+# name: wdmycloudex2VolumeNum
68
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.1
69
+# tag: wdmycloudex2_volume_num
70
+# - symbol:
71
+# name: wdmycloudex2VolumeName
72
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.2
73
+# tag: wdmycloudex2_volume_name
74
+# - symbol:
75
+# name: wdmycloudex2VolumeFsType
76
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.3
77
+# tag: wdmycloudex2_volume_fs_type
78
+# - symbol:
79
+# name: wdmycloudex2VolumeRaidLevel
80
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.9.1.4
81
+# tag: wdmycloudex2_volume_raid_level
82
142
-metric_tags:
143
- - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.1.0
144
- symbol: wdmycloudex2AgentVer
145
- tag: wdmycloudex2_agent_ver
146
- - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.2.0
147
- symbol: wdmycloudex2SoftwareVersion
148
- tag: wdmycloudex2_software_version
149
- - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.3.0
150
- symbol: wdmycloudex2HostName
151
- tag: wdmycloudex2_host_name
152
- - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.5.0
153
- symbol: wdmycloudex2FTPServer
154
- tag: wdmycloudex2_ftp_server
155
- mapping:
156
- 0: disable
157
- 1: enable
158
- # mapping in the metric description
159
- - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.6.0
160
- symbol: wdmycloudex2NetType
161
- tag: wdmycloudex2_net_type
162
- mapping:
163
- 0: workgroup
164
- 1: active_directory
165
- # mapping in the metric description
83
+# - MIB: WDMYCLOUDEX2-MIB
84
+# table:
85
+# name: wdmycloudex2DiskTable
86
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10
87
+# symbols:
88
+# # - OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.5
89
+# # name: wdmycloudex2DiskTemperature
90
+# # string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
91
+# - name: wdmycloudex2Disk
92
+# constant_value_one: true
93
+# metric_tags:
94
+# - symbol:
95
+# name: wdmycloudex2DiskNum
96
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.1
97
+# tag: wdmycloudex2_disk_num
98
+# - symbol:
99
+# name: wdmycloudex2DiskVendor
100
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.2
101
+# tag: wdmycloudex2_disk_vendor
102
+# - symbol:
103
+# name: wdmycloudex2DiskModel
104
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.3
105
+# tag: wdmycloudex2_disk_model
106
+# - symbol:
107
+# name: wdmycloudex2DiskSerialNumber
108
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.4
109
+# tag: wdmycloudex2_disk_serial_number
110
+# - symbol:
111
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.10.1.6
112
+# name: wdmycloudex2DiskCapacity
113
+# tag: wdmycloudex2_disk_capacity
114
+
115
+# - MIB: WDMYCLOUDEX2-MIB
116
+# table:
117
+# name: wdmycloudex2UPSTable
118
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11
119
+# symbols:
120
+# - name: wdmycloudex2UPS
121
+# constant_value_one: true
122
+# # - name: wdmycloudex2UPSBatteryCharge
123
+# # OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.5
124
+# # string metric is not supported yet (keep this metric and this comment in profile until it's fixed)
125
+# metric_tags:
126
+# - symbol:
127
+# name: wdmycloudex2UPSNum
128
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.1
129
+# tag: wdmycloudex2_ups_num
130
+# - symbol:
131
+# name: wdmycloudex2UPSMode
132
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.2
133
+# tag: wdmycloudex2_ups_mode
134
+# - symbol:
135
+# name: wdmycloudex2UPSManufacturer
136
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.3
137
+# tag: wdmycloudex2_ups_manufacturer
138
+# - symbol:
139
+# name: wdmycloudex2UPSProduct
140
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.4
141
+# tag: wdmycloudex2_ups_product
142
+# - symbol:
143
+# name: wdmycloudex2UPSStatus
144
+# OID: 1.3.6.1.4.1.5127.1.1.1.8.1.11.1.6
145
+# tag: wdmycloudex2_ups_status
src/go/plugin/go.d/config/go.d/snmp.profiles/default/zebra-printer.yaml
+44
-42
@@ -1,11 +1,16 @@
1
extends:
2
- _system-base.yaml
3
4
+sysobjectid:
5
+ - 1.3.6.1.4.1.10642.1.1 # ZT410-203dpi ZPL
6
+
7
metadata:
8
device:
9
fields:
10
vendor:
11
value: "zebra"
12
+ type:
13
+ value: "printer"
14
version:
15
symbol:
16
MIB: ZEBRA-MIB
@@ -21,35 +26,56 @@ metadata:
26
MIB: ZEBRA-MIB
27
OID: 1.3.6.1.4.1.10642.1.18.0
28
name: zbrGeneralLINKOSVersion
24
- type:
25
- value: "printer"
29
27
-sysobjectid:
28
- - 1.3.6.1.4.1.10642.1.1 # ZT410-203dpi ZPL
30
metrics:
31
- MIB: ZEBRA-MIB
32
table:
33
name: zbrTrackedAlertsTable
34
OID: 1.3.6.1.4.1.10642.10.31
35
symbols:
35
- - name: zbrTrackedAlerts
36
- constant_value_one: true
37
- description: "Number of tracked alerts"
38
- unit: "{alert}"
39
- # TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
40
- metric_tags:
41
- - symbol:
42
- OID: 1.3.6.1.4.1.10642.10.31.1.2
43
- name: zbrTrackedAlertsSeverity
44
- tag: zbr_tracked_alerts_severity
36
+ - OID: 1.3.6.1.4.1.10642.10.31.1.2
37
+ name: zbrTrackedAlertsSeverity
38
+ chart_meta:
39
+ description: The severity level of tracked alerts
40
+ family: Alert/Severity/Status
41
+ unit: "{status}"
42
mapping:
43
1: other
44
3: critical
45
4: warning
49
- - symbol:
46
+ - OID: 1.3.6.1.4.1.10642.10.31.1.5
47
+ name: zbrTrackedAlertsCode
48
+ chart_meta:
49
+ description: The code associated with tracked alerts
50
+ family: Alert/Code/Status
51
+ unit: "{status}"
52
+ mapping:
53
+ 1: paper-out
54
+ 2: ribbon-out
55
+ 3: head-too-hot
56
+ 4: head-under-temp
57
+ 5: head-open
58
+ 6: power-supply-over-temp
59
+ 7: motor-over-temp
60
+ 8: ribbon-in
61
+ 9: rewind-fault
62
+ 10: cutter-jammed
63
+ 11: printer-paused
64
+ 12: head-element-bad
65
+ 13: basic-runtime
66
+ 14: basic-forced
67
+ 15: power-on
68
+ 16: battery-low
69
+ 17: rfid-error
70
+ 18: cold-start
71
+ 19: ribbon-auth-error
72
+ metric_tags:
73
+ - tag: zbr_alert_index
74
+ index: 1
75
+ - tag: zbr_tracked_alerts_training_level
76
+ symbol:
77
OID: 1.3.6.1.4.1.10642.10.31.1.3
78
name: zbrTrackedAlertsTrainingLevel
52
- tag: zbr_tracked_alerts_training_level
79
mapping:
80
1: other
81
2: unknown
@@ -57,10 +83,10 @@ metrics:
83
4: trained
84
5: field_service
85
6: management
60
- - symbol:
86
+ - tag: zbr_tracked_alerts_group
87
+ symbol:
88
OID: 1.3.6.1.4.1.10642.10.31.1.4
89
name: zbrTrackedAlertsGroup
63
- tag: zbr_tracked_alerts_group
90
mapping:
91
1: system
92
2: media
@@ -71,27 +97,3 @@ metrics:
97
7: zbi
98
8: battery
99
9: rfid
74
- - symbol:
75
- OID: 1.3.6.1.4.1.10642.10.31.1.5
76
- name: zbrTrackedAlertsCode
77
- tag: zbr_tracked_alerts_code
78
- mapping:
79
- 1: paper-out
80
- 2: ribbon-out
81
- 3: head-too-hot
82
- 4: head-under-temp
83
- 5: head-open
84
- 6: power-supply-over-temp
85
- 7: motor-over-temp
86
- 8: ribbon-in
87
- 9: rewind-fault
88
- 10: cutter-jammed
89
- 11: printer-paused
90
- 12: head-element-bad
91
- 13: basic-runtime
92
- 14: basic-forced
93
- 15: power-on
94
- 16: battery-low
95
- 17: rfid-error
96
- 18: cold-start
97
- 19: ribbon-auth-error
src/go/plugin/go.d/config/go.d/snmp.profiles/default/zyxel-switch.yaml
+30
-25
@@ -2,6 +2,9 @@ extends:
2
- _system-base.yaml
3
- _std-if-mib.yaml
4
5
+sysobjectid:
6
+ - 1.3.6.1.4.1.890.1.15 # ZyWALL Switch (Generic)
7
+
8
metadata:
9
device:
10
fields:
@@ -10,37 +13,39 @@ metadata:
13
type:
14
value: "switch"
15
13
-sysobjectid:
14
- - 1.3.6.1.4.1.890.1.15 # ZyWALL Switch (Generic)
15
-metrics:
16
- - MIB: ZYXEL-ES-COMMON
17
- symbol:
18
- name: cpu.usage
19
- OID: 1.3.6.1.4.1.890.1.15.3.2.4.0
20
- description: Device CPU usage (%)
21
- unit: "%"
22
- - MIB: ZYXEL-ES-COMMON
23
- symbol:
24
- name: memory.usage
25
- OID: 1.3.6.1.4.1.890.1.15.3.2.5.0
26
- description: Device memory usage (%)
27
- unit: "%"
28
-
29
-# TODO: Check out metric_tags with symbols having mappings and/or expressing states/statuses. Need to convert to metrics.
16
metric_tags:
31
- - OID: 1.3.6.1.4.1.890.1.15.3.1.1.0
17
+ - tag: zyxel_sys_sw_platform
18
+ OID: 1.3.6.1.4.1.890.1.15.3.1.1.0
19
symbol: sysSwPlatform
33
- tag: zyxel_sys_sw_platform
20
mapping:
21
1: other
22
2: zynos
23
3: zld
38
- - OID: 1.3.6.1.4.1.890.1.15.3.1.6.0
24
+ - tag: zyxel_sys_sw_version_string
25
+ OID: 1.3.6.1.4.1.890.1.15.3.1.6.0
26
symbol: sysSwVersionString
40
- tag: zyxel_sys_sw_version_string
41
- - OID: 1.3.6.1.4.1.890.1.15.3.1.11.0
27
+ - tag: zyxel_sys_product_model
28
+ OID: 1.3.6.1.4.1.890.1.15.3.1.11.0
29
symbol: sysProductModel
43
- tag: zyxel_sys_product_model
44
- - OID: 1.3.6.1.4.1.890.1.15.3.1.12.0
30
+ - tag: zyxel_sys_product_serial_number
31
+ OID: 1.3.6.1.4.1.890.1.15.3.1.12.0
32
symbol: sysProductSerialNumber
46
- tag: zyxel_sys_product_serial_number
33
+
34
+metrics:
35
+ - MIB: ZYXEL-ES-COMMON
36
+ symbol:
37
+ name: cpu.usage
38
+ OID: 1.3.6.1.4.1.890.1.15.3.2.4.0
39
+ chart_meta:
40
+ description: Device CPU usage (%)
41
+ family: CPU/Usage
42
+ unit: "%"
43
+
44
+ - MIB: ZYXEL-ES-COMMON
45
+ symbol:
46
+ name: memory.usage
47
+ OID: 1.3.6.1.4.1.890.1.15.3.2.5.0
48
+ chart_meta:
49
+ description: Device memory usage (%)
50